Huawei Ekit Unmanaged Switch S110-8P2ST (98012269) Original price was: ₦160,000.00.Current price is: ₦150,500.00.
Back to products
Huawei Ekit Unmanaged Switch S110-24LP2SR (98012198) Original price was: ₦360,000.00.Current price is: ₦350,500.00.

Huawei Ekit Unmanaged switch S110-16LP2SR (98012197)

Original price was: ₦260,000.00.Current price is: ₦242,000.00.

Part Number
98012197
Model
S110-16LP2SR
Description
S110-16LP2SR (16*10/100/1000BASE-T ports, 2*GE SFP ports, PoE+, AC power)
0 People watching this product now!

Fast Shipping

Carrier information

Secure Shopping

You're in safe hands

online support

24/7 Support

Unlimited help desk

Description

Basic Information
Part Number
98012197
Model
S110-16LP2SR
Description
S110-16LP2SR (16*10/100/1000BASE-T ports, 2*GE SFP ports, PoE+, AC power)
Technical Specifications
Chassis material
Metal
Height [mm]
43.6 mm
Depth [mm]
260.0 mm
Wide [mm]
442.0 mm
Chassis height [U]
1
Weight with packaging [kg(lb)]
3.7 (8.16)
Weight without packaging [kg(lb)]
3.0 (6.61)
Maximum power consumption [W]
Without PoE: 22.0 W
Full PoE load: 160.0 W (PoE: 124 W)
Typical power consumption [W]
22.0
Heat dissipation mode
Natural heat dissipation
Maximum heat dissipation [BTU/hour]
Without PoE: 75.07
Full PoE load: 545.94
Typical heat dissipation [BTU/hour]
75.07
Power supply mode
AC built-in
Input voltage range [V]
AC input: 90 V AC to 300 V AC; 47 Hz to 63 Hz
Rated input voltage [V]
AC input: 100–240 V AC; 50/60 Hz
Maximum input current [A]
3 A
Number of power slots
0
Number of card slots
0
Memory
-
Flash memory
-
Redundant power supply
Not supported
Types of fans
None
Noise at normal temperature (acoustic power) [dB(A)]
Noise-free (no fans), < 30
Noise at normal temperature (acoustic pressure) [dB(A)]
Noise-free (no fans), < 20
Airflow direction
-
Storage temperature [°C(°F)]
–40°C to +70°C (–40°F to +158°F)
Long-term operating temperature [°C(°F)]
0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.)
Restriction on the operating temperature variation rate [°C(°F)]
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
Long-term operating relative humidity [RH]
5% RH to 95% RH (non-condensing)
Storage altitude [m(ft.)]
0-5000 m (0-16404 ft.)
Long-term operating altitude [m(ft.)]
0–5000 m (0–16404 ft.)
MTBF [year]
57.77
MTTR [hour]
2
Availability
> 0.99999
Maximum number of physical ports on the entire device
18
Maximum number of 100GE ports
0
Maximum number of 40GE ports
0
Maximum number of 25GE ports
0
Maximum number of 10GE ports
0
Maximum number of GE ports
18
Maximum number of FE ports
18
Downlink ports
16 x 10/100/1000BASE-T ports (124 W PoE+)
Uplink ports
2 x GE SFP ports
USB
Not supported
Console port
Not supported
Eth Management port
Not supported
Working mode
- Standard mode
- Port isolation
- Uplink aggregation
- Flow control disabling
MAC address entry
8K
Service port surge protection [kV]
Common mode: ±4 kV
Power supply surge protection
Differential mode: ±6 kV; common mode: ±6 kV
RPS input
Not supported
PoE
Supported
Additional information
Brand

PORTS

16 ports

RELATED PRODUCTS